FLAGSHIP INDUSTRIAL CO-GENERATION

Project Atlantis

Turning Data Center Waste Heat into a Water Infrastructure Opportunity

Project Atlantis is an industrial-scale atmospheric water generation concept engineered to integrate directly with hyperscale data centers and high-density industrial facilities—converting server waste heat into a continuous, on-site water resource.

The Host Priority Rule: The Atlantis platform is governed by an unconditional systems-safety constraint: the host facility's primary thermal rejection pathways can never be compromised.
5-STAGE PROCESS INTEGRATION
01 • THERMAL INTERCEPT (55°C – 80°C)
↓
02 • DOUBLE-WALL HEAT EXCHANGER BARRIER
↓
03 • LIQUID DESICCANT REGENERATION
↓
04 • MOISTURE EXTRACTION & CONDENSATION
↓
05 • PURIFICATION & LOOP RE-INJECTION
INFRASTRUCTURE BOTTLENECK

The Water and Cooling Challenge Facing AI Infrastructure

As artificial intelligence compute clusters transition from air cooling to liquid-to-chip manifolds, power densities are reaching 50 to 100+ kW per rack. Evaporative cooling towers remain the thermodynamic workhorse for hyperscale campuses, consuming between 1 million and 5 million gallons of municipal water per day per campus.

This unprecedented demand collides with regional water scarcity. In key digital infrastructure corridors—such as Northern Virginia, Phoenix, Nevada, and Texas—local utilities are enforcing stringent extraction caps, steep rate hikes, and moratoriums on new permits.

Project Atlantis is a proposed thermal co-generation platform being evaluated for potential integration with suitable data-center cooling systems and industrial waste-heat sources. The concept is intended to use available thermal energy to support atmospheric water generation. Actual water output, auxiliary electrical demand, and effects on the host system depend on the final design and must be validated under defined operating conditions.

AI Cluster Thermal Metrics (Modeled Target)

CHIP MANIFOLD EXHAUST: 55°C – 80°C Hot Fluid Return
CONVENTIONAL WATER WITHDRAWAL: Up to 3,000,000 gal/day per 100MW
ATLANTIS THERMAL CONSUMPTION: Zero Grid Fossil Heat Needed
WUE IMPACT: Measurable Net Withdrawal Reduction
DETAILED THERMODYNAMICS

How Project Atlantis Works: The 5-Step Cycle

01

Thermal Intercept

Hot fluid from server liquid cooling loops (55°C–80°C) is intercepted before conventional cooling towers, capturing thermal energy before atmospheric dissipation.

02

Heat Exchanger Barrier

The proposed design uses segregated fluid circuits and engineered heat-transfer interfaces intended to reduce the risk of fluid mixing. Final pressure-boundary design, isolation performance, and applicable certification requirements must be verified through engineering review and testing.

03

Desiccant Regeneration

Transferred heat elevates the temperature of the moisture-saturated liquid desiccant, driving off captured atmospheric water vapor in a sealed desorption tower.

04

Moisture Recovery

Desorbed water vapor passes into a specialized condensation chamber, where ambient or auxiliary cooling condenses pure liquid water with minimal electric demand.

05

Purification & Re-injection

Condensate undergoes sub-micron filtration and UV sanitation, feeding demineralized water directly back into facility cooling loops or potable storage.

ENGINEERING RIGOR

The Atlantis Engineering Difference

Physical Fluid Isolation

Host server coolants and ATAP liquid desiccant never share a single-wall boundary. Intermediate vented chambers detect any microscopic leak before cross-contamination can occur.

Fail-Safe Cooling Bypass

The system is designed around a mechanically biased bypass intended to prioritize host-system cooling during defined fault conditions. Response time, bypass operation, and pressure-drop performance remain subject to verification under the applicable operating and fault scenarios.

Automated Monitoring & Control

Redundant PLC controllers with triple-sensor voting logic continuously track temperatures, pressure differentials, and flow rates with remote SCADA telemetry.

Structured Hazard Assessment

Aerospace FMECA protocols map every mechanical valve, electrical relay, and sensor failure mode, ensuring every single subsystem has an unpowered safe state.

VALUE PROPOSITION

Five Core Infrastructure Benefits

BENEFIT 01

Net Water Withdrawal Reduction (WUE)

Generates high-purity water directly on-site to offset cooling tower evaporation, lowering net withdrawal and dramatically improving Water Usage Effectiveness metrics.

BENEFIT 02

Low Host Thermal Risk

Mechanically biased fail-safe open bypass guarantees host facility cooling continues with zero thermal or hydraulic impedance under all operating conditions.

BENEFIT 03

On-Site Supplemental/Water Generation

Decouples facility operations from municipal grid water caps, regional drought mandates, and supply line disruptions without drilling or extraction permits.

BENEFIT 04

Valorization of Low-Grade Heat (55°C–80°C)

Potential operating-cost and water-savings benefits depend on site conditions, energy prices, water requirements, system configuration, and validated performance data.

BENEFIT 05

Modular, Standardized Form Factor

Packaged into standard 20ft and 40ft ISO containerized skids for rapid shipping, standardized crane rigging, and linear scalability across campus expansions.

COMMERCIALIZATION

Cooling-as-a-Service (CaaS) Delivery Model

Deploying Project Atlantis does not require hyperscale asset managers to absorb speculative capital expenditures. Through our Cooling-as-a-Service (CaaS) model, ATAP partners with infrastructure capital providers to finance, construct, and operate thermal-intercept skids.

Host facilities pay a predictable operational fee tied to measured thermal rejection and gallons of high-purity water delivered back into plant cooling loops.

FROM ARCHITECTURE TO INFRASTRUCTURE
PHASE 1 • VALIDATED Thermodynamic Simulation & Desiccant Cycle Benchmarking
PHASE 2 • CURRENT FOCUS Prototype Skid Fabrication & Fail-Safe Mechanical Bypass Verification
PHASE 3 • HOST PILOT Data Center Host Thermal Intercept Field Demonstration
PHASE 4 • SCALED COMMERCIAL Modular Series Manufacturing with Cooling OEMs & EPC Partners
SAM.gov Federal Registry
Active Federal Entity / UEI Verified
CAGE Code: 9VK82
State of California
Certified Small Business (SB)
DGS Ref: #2034981 • CA Entity
NAICS Classifications
221310 • 333318 • 541330
Water • Machinery • Systems Eng
Intellectual Property
Liquid Desiccant AWG
Thermal Bypass Patents Pending