Technology & Solutions
ATAP approaches atmospheric water generation as an integrated infrastructure system—combining advanced thermodynamics, fail-safe host protection, and proven industrial applications.
Unlike conventional refrigerant dehumidifiers that freeze or fail below 40% RH, ATAP's hygroscopic liquid-desiccant core operates efficiently across an exceptionally broad humidity spectrum.
Our Technology Platforms
We engineer two distinct hardware platforms: the standalone ATAP Gen-2 unit for decentralized deployment, and Project Atlantis for industrial thermal co-generation. Specifications are maintained distinctly.
ATAP Gen-2 Atmospheric Water Generator
The ATAP Gen-2 is a fully autonomous, skid-mounted atmospheric water generator engineered for point-of-need operations where municipal pipelines do not exist or municipal supply is compromised. Utilizes high-surface-area liquid desiccant contactors to harvest pure atmospheric moisture across extreme climate profiles.
| NOMINAL CAPACITY | 1,000 Gallons / Day (3,785 L/day) |
| OPERATING HUMIDITY RANGE | Operating Humidity Range: To Be Validated |
| POWER DEMAND | 27 kW continuous rated load |
| PURITY COMPLIANCE | Water Quality Testing and Applicable Standards: To Be Confirmed |
| REGULATORY CODE | SAM.gov Registered • CAGE: 9VK82 |
Project Atlantis™ Platform
Project Atlantis is an industrial-scale thermal co-generation platform engineered to integrate directly with data center cooling loops and industrial waste heat stacks. Designed to integrate thermal recovery with auxiliary electrical loads that depend on the final system configuration.
| THERMAL SOURCE COMPATIBILITY | 55°C-80°C Liquid / Exhaust Gas |
| SCALED DAILY OUTPUT | Illustrative Modular Capacity: Subject to Engineering Validation |
| HOST PROTECTION SYSTEM | Mechanically Biased Bypass Architecture |
| FLUID CIRCUIT SECURITY | Double-Wall Heat-Transfer Isolation: Specification and Certification To Be Confirmed |
| COMMERCIAL STRUCTURE | Cooling-as-a-Service (CaaS) / Off-Take |
Engineering & Systems Safety
Derived from mission-critical aerospace systems safety and process engineering where downtime is intolerable. Reliability is engineered into the architecture before it is demonstrated.
Physically Isolated Fluid Circuits
The proposed controls architecture may incorporate temperature, pressure, and flow monitoring, fault detection, and supervisory diagnostics. Final instrumentation, redundancy, and control logic will be defined and verified during detailed engineering.
Fail-Safe Cooling Priority
The system is designed around a mechanically biased bypass intended to prioritize host-system cooling during defined fault conditions. Response time, bypass behavior, and pressure-drop performance must be established through documented engineering analysis and testing.
Safety-Led Controls & SCADA
Edge PLC automation with 2-out-of-3 voting logic. Redundant 2-out-of-3 voting logic prevents false actuations while satellite and cellular SCADA provides continuous predictive maintenance diagnostics.
Industry Applications
Tailored deployment architectures addressing acute operational friction across four high-value commercial and government domains.
Data Centers & AI Infrastructure
ATAP Solution: The Atlantis Co-Gen architecture captures 55°C–80°C server exhaust heat via double-wall plate heat exchangers to regenerate liquid desiccant, creating on-site high-purity water to feed cooling loops without grid withdrawal.
Industrial Facilities
ATAP Solution: Co-locating skid-mounted AWG modules adjacent to boiler stacks, diesel gen-sets, or compressor exhausts, converting waste heat into high-purity process water.
Defense & Remote Operations
ATAP Solution: Ruggedized, air-droppable ISO containerized Gen-2 AWG modules engineered to military standards (TB MED 577 potability, CAGE 9VK82, SAM.gov registered) for point-of-need independence.
Decentralized Utilities & Water-Constrained Locations
ATAP Solution: Decentralized supplemental water arrays directly tied into district distribution points or public reservoirs, powered by municipal solar or waste-to-energy facilities without ground disturbance.
ATAP Gen-2 Nominal Capacity Calculator
Estimate nominal daily and annual water generation volumes, electrical operating demands, and gross water value based on deployed Gen-2 module quantities and operating schedules.